nybjtp

Copper (Aluminum) Dense Busbars and Rated Current 250A~6300A

short description:

Busbars are widely used in transmission and distribution systems. The sandwich structure used inside is reasonably designed with superior performance, featuring stability and reliability, high distribution efficiency, good heat dissipation, voltage reduction, resistance to mechanical shock and easy installation, etc. Current levels range from 250A to 6300A, which can meet the electricity demand of different user groups.


Product Detail

Product Tags

Product Pictures(Seven Types)

Aluminum-Dense-Busway2

Tee Elbow

Aluminum-Dense-Busway3

Special Knee (up/down)

Aluminum-Dense-Busway4

Horizontal Elbow

Aluminum-Dense-Busway5

Panel Connection

Aluminum-Dense-Busway6

Straight Length Busbar

Aluminum-Dense-Busway1

Straight Length Busbar With Plugs

Aluminum-Dense-Busway7

Vertical Elbow

Product Parameters

Executive standard IEC61439-6,GB7251.1,HB7251.6
System Three-phase three-wire, three-phase four-wire, three-phase five-wire, three-phase five-wire (shell as PE)
Rated frequency f(Hz) 50/60
Rated insulation voltage Ui(V) 1000
Rated working voltage Ue(V) 380-690
current(A) 250A~6300

Other Parameters

Material Cu or Aluminum
Ambient temperature ≤40℃,average not more than 35℃ in 24 hours
Voltage Category

/Pollution Degree

Ⅲ/3
Protection class IP54、IP55、IP65、IP66
Color Electrostatic powder coating, default RAL7035 light gray, can be customized
Installation method Horizontal hanging bracket, spring bracket

Plug Parameters

Rated working voltageUe(V) 400
Plug box current(A) 16-1600
Socket configuration Standard 3 meters long straight section, 1-10 sockets can be set on the front and back

 

Current level(A) Product Name Dense Busway/4P Dense Busway/5P
Dimensions Wide(mm) High(mm) Wide(mm) High(mm)
250A 128 97 128 97
400A 128 102 128 102
500A 128 107 128 107
630A 128 102 128 102
800A 128 112 128 112
1000A 128 122 128 122
1250A 128 142 128 142
1600A 128 157 128 157
2000A 128 192 128 192
2500A 128 237 128 237
3150A 128 302 128 302
4000A 128 372 128 372
5000A 128 462 128 462
6300A 128 582 128 582

Attachments

product-description1

End Cap

product-description2

Connector

product-description3

Plug In

product-description4

Plug In Unit

product-description5

Hard Connection

product-description6

Vertical Fix Hanger

product-description7

Vertical Spring Hanger

product-description8

Expansion Joint

product-description9

Flance End Box

product-description10

Soft Connection

Advantage

Sandwich conductor structure

  • Full-length dense, no chimney effect
  • Compact structure, occupying less space in the building
  • Close arrangement of conductors, overall heat dissipation, lower temperature rise
  • No bending of the bus bar at the socket, high density and low impedance
  • Anti-phase design to ensure correct phase sequence during installation
  • The current-carrying capacity is not affected by the installation location and mounting method
product-description11

Aluminum-magnesium alloy housing

  • The bus bar is made of light-weight, extruded aluminum-magnesium alloy profile as the shell, with a thickness of not less than 2mm, which has high mechanical strength and can cope with various special application conditions with ease.
  • The painted housing has excellent corrosion resistance and can withstand 1200 hours of salt spray testing
  • With a serrated heat sink, heat dissipation area is 1.5 times the ordinary shell, heat dissipation, improve the current-carrying capacity has excellent electrical conductivity, the overall shell is not less than 50% of the phase line grounding capacity
  • Aluminum alloy shell is non-magnetic environmental protection material, can effectively avoid the impact of eddy current and hysteresis loss on the busbar
product-description12

Single bolt connectors

  • Adopt single bolt clamping mechanism, fast and reliable installation, double the speed of traditional connectors
  • Adopt double-headed fixed-torque bolts, equipped with special disc springs to greatly improve the compressive strength
  • Separate temperature indicator module available to alert in case of system failure or high temperature
  • Connecting bus bar cross-section is more than 1.2 times of bus bar cross-section of bus bar system, and the contact surface is double-sided lap joint, which effectively reduces the contact resistance
  • Increased creepage distance by adding grooves to the edges of the insulation partition
product-description13

Unique anti-phase device
The correctness of phase sequence is directly related to the operation safety of busbar system. The anti-phase device of the busbar system of Sunshine Electric can effectively eliminate the harm caused by human factors and avoid the phase sequence error.

product-description14

Reliable insulation materials

  • Adopt standard class B (120℃) insulation material
  • Double wrapped, up to four layers between phases to ensure insulation reliability
  • The insulation material is heat-resistant grade B, and the voltage resistance of a single layer can be more than 10KV, which is the professional electrical insulation material recommended by the International IEC Association.
  • Non-toxic, does not produce harmful substances even at high temperatures
product-description15

Reliable tap unit

  • Bimetallic pin construction with silver-plated surface ensures long-lasting contact pressure and low contact resistance
  • Equipped with a safety chain mechanism, plug box is not installed in place, can not close the gate, can effectively avoid plug box with load plugging
  • Anti-phase design, to ensure that the plug box plugging error-free
  • Plug box all live parts are effective electrical isolation, plug box installation, its ground line before the phase line and busbar system connected, plug box disconnect, ground line after disconnect
product-description16

  • Previous:
  • Next:

  • Write your message here and send it to us